Cyclic Fatigue Resistance of Hyflex EDM and ProTaper Gold Files at Different Locations of Canal Curvature

Authors

  • Ahmed A. Malik A. Malik MSc student at Department of conservative Dentistry, College of Dentistry, Mustansiriyah University
  • Iman M. Al Zaka Prof. at Department of Conservative Dentistry, College of Dentistry, Mustansiriyah University, Baghdad, Iraq.

DOI:

https://doi.org/10.32828/mdj.v18i2.919

Keywords:

Cyclic fatigue, curvature location, nickel-titanium file, ProTaper Gold, Hyflex EDM

Abstract

Aim: Study's purpose was to evaluate and compare the fatigue resistance of ProTaper Gold and Hyflex EDM files at five different locations of canal curvature.

Methods: Two types of NiTi files; ProTaper Gold and Hyflex EDM (n=80) with similar sizes (25/0.08) were used as two main groups (n=40), each group subdivided into five subgroups (n=8) according to distance from the orifice to curvature which are; 11, 10, 8, 6 and 5 mm. Five stainless steel canals were fabricated. Each canal had 16 mm length, 1.5 mm width and single curvature with 3-mm radius and 60° angle.  Fractured samples were examined under a scanning electron microscope. Independent t-test, One-way ANOVA and Posthoc tests assessed the data statistically.

Results: Number of cycles to fatigue for the Hyflex EDM file was significantly higher than the ProTaper Gold file at all curvature levels (p≤0.05). The files demonstrated significantly higher number of cycles to fatigue in canals of (10 and 11) mm when compared to the canals of (5, 6, and 8) mm (p≤0.05).

Conclusion: Hyflex EDM files showed higher fatigue resistance than ProTaper Gold files. The canal curvature position had a substantial impact on the resistance of the NiTi file, with short life coronally.

References

Navos BV, Hoppe CB, Mestieri LB, Bottcher DE, So MV, Grecca FS. Centering and transportation: in vitro evaluation of continuous and reciprocating systems in curved root canals. J Conserv Dent. 2016; 19 (5): 478- 481.

Walia HM, Brantley WA, Gerstein H. An initial investigation of the bending and torsional properties of Nitinol root canal files. J Endod. 1988; 14(7): 346-351.‏

Bukhari KA, Almalki MA, Daghestani MH, Bogari DF, Aljifan MK, Alharbi YM et al. Cyclic fatigue comparison of different manufactured endodontic files. Saudi Endod J. 2019; 9: 186-191.

Bueno CRE, Cury MTS, Vasques AMV, Sivieri-Araújo G, Jacinto RC, Gomes-Filho JE et al. Cyclic fatigue resistance of novel Genius and Edgefile nickel-titanium reciprocating instruments. Braz oral res. 2019; 33: 1-9.

Lopes HP, Ferreira AA, Elias CN, Moreira EJ, de Oliveira JCM, Siqueira JF. Influence of Rotational Speed on the Cyclic Fatigue of Rotary Nickel-Titanium Endodontic Instruments. J Endod. 2009; 35: 1013-1016.‏

Cheung GSP, Peng B, Bian Z, Shen Y, Darvell BW. Defects in ProTaper S1 instruments after clinical use: fractographic examination. Int Endod J. 2005; 38: 802-809.

Park SY, Cheung GS, Yum J, Hur B, Park JK, Kim HC. Dynamic torsional resistance of nickel-titanium rotary instruments. J Endod. 2010; 36: 1200-1204.

Alqedairi A, Alfawaz H, Bin Rabba A, Almutairi A, Alnafaiy S, Khan Mohammed M. Failure analysis and reliability of Ni–Ti-based dental rotary files subjected to cyclic fatigue. Metals. 2018; 8: 1-36.

Pedulla E, Savio FL, Boninelli S, Politino G, Grande NM, La Rosa G et al. Torsional and cyclic fatigue resistance of a new nickel-titanium instrument manufactured by electrical discharge machining. J Endod. 2016; 42: 156-159.

Alghamdi S, Huang X, Haapasalo M, Mobuchon C, Hieawy A, Hu J et al. Effect of curvature location on fatigue resistance of five nickel-titanium files determined at body temperature. J Endod. 2020; 46(11): 1682-1688.

Blašković-Šubat, Višnja. Frequency and most common localisation of root canal curvature. Acta stomatologica Croatica. IJOS. 1991; 25(2): 109-115. ‏

Divine KA, McClanahan SB, Fok A. Anatomic analysis of palatal roots of maxillary molars using micro–computed tomography. J Endod. 2019; 45(6): 724-728.

Altaay AO, Shukri BM. The Effect of Different Curvature Levels on Cyclic Fatigue of Three Single File NiTi Instruments (A comparative study). Int Med J. 2020; 25(05): 2388- 2391.

Sobotkiewicz T, Huang X, Haapasalo M, Mobuchon C, Hieawy A, Hu J et al. Effect of canal curvature location on the cyclic fatigue resistance of reciprocating files. Clin Oral Invest. 2021; 25: 169-177.

Bhagabati N, Yadav S, Talwar S. An in vitro cyclic fatigue analysis of different endodontic nickel-titanium rotary instruments. J Endod. 2012; 38(4): 515-518.

Shen Y, Huang X, Wang Z, Wei X, Haapasalo M. Low environmental temperature influences the fatigue resistance of nickel-titanium files. J Endod. 2018; 44: 626-629.

Zupanc J, Vahdat-Pajoh N, Schäfer E. New thermomechanically treated NiTi alloys a- Review. Int Endod J. 2018; 51(10): 1088-1103.

De-Vasconcelos RA, Murphy S, Carvalho CAT, Govindjee RG, Govindjee S, Peters OA. Evidence for reduced fatigue resistance of contemporary rotary instruments: exposed to body temperature. J Endod. 2016; 42(5): 782-787.

Iacono F, Pirani C, Generali L, Bolelli G, Sassatelli P, Lusvarghi L et al. Structural analysis of HyFlex EDM instruments. Int Endod J. 2017; 50(3): 303-313.

Shen Y, Zhou H-m, Zheng Y-f, Peng B, Haapasalo M. Current Challenges and Concepts of the Thermomechanical Treatment of Nickel-Titanium Instruments. J Endod. 2013; 39(2): 163-172.

Madarati AA, Watts DC, Qualtrough AJE. Factors contributing to the separation of endodontic files. B D J. 2008; 204(5): 241-245.

Gao Y, Cheung GS, Shen Y, Zhou X. Mechanical behavior of ProTaper universal F2 finishing file under various curvature conditions: a finite element analysis study. J Endod. 2011; 37(10): 1446-1450.

Higuera O, Plotino G, Tocci L, Carrillo G, Gambarini G, Jaramillo DE. Cyclic fatigue resistance of 3 different nickel-titanium reciprocating instruments in artificial canals. J Endod. 2015; 41(6): 913-915.

Downloads

Published

28.12.2022

How to Cite

A. Malik, A. A. M., & M. Al Zaka, I. . (2022). Cyclic Fatigue Resistance of Hyflex EDM and ProTaper Gold Files at Different Locations of Canal Curvature. Mustansiria Dental Journal, 18(2), 167–175. https://doi.org/10.32828/mdj.v18i2.919